Industrial Roof Electric Skylight Arched Side Open Daylighting Ventilation Skylight
Product Summary
Arched Side‑Open Daylighting & Ventilation Skylight | Industrial Roof Vent Window The arched side‑open skylight is a ridge‑mount industrial roof ventilation unit widely used for steel‑structure workshops. The arched profile optimizes hot‑air buoyancy exhaust effect, realizing large‑scale passive ...
Product Custom Attributes
Arched Side Open Electric Skylight
,Daylighting Ventilation Roof Skylight
,Industrial Roof Electric Skylight
Product Description
The arched side‑open skylight is a ridge‑mount industrial roof ventilation unit widely used for steel‑structure workshops. The arched profile optimizes hot‑air buoyancy exhaust effect, realizing large‑scale passive ventilation and natural daylighting. It effectively reduces indoor heat accumulation, lowers mechanical ventilation energy consumption, and adapts to long‑term outdoor industrial‑building operation environment.
This arched side‑opening skylight is mainly installed along building roof ridge. Under normal conditions, side‑opening sash can open for natural exhaust of hot air, moisture and workshop waste gas. When rainfall occurs, sashes fully close to guarantee roof waterproof performance. Continuous modular layout can be customized according to workshop ventilation demand, widely adopted for thermal‑dissipation transformation of newly‑built and existing industrial plants.
Hot‑dip galvanized steel profile or aluminum alloy frame, anti‑corrosion coating treatment, arched streamline shape reduces wind load impact.
Anti‑UV FRP panel or multi‑wall polycarbonate sheet, good light transmission and weather resistance, slow aging under long‑time sunlight exposure.
Side‑hinged sash structure, matched heavy‑duty electric push‑rod driving system; multi‑sash can realize synchronous opening‑closing control.
Built‑in water‑collecting trough collects rainwater and condensate water, guides water to external drainage outlet; multi‑track sealing strips reduce rain‑splash risk.
Galvanized base frame, convenient for welding or bolting connection with roof purlin, reserve operation space for on‑site waterproof treatment.
- Arched streamline structure takes advantage of hot‑air buoyancy for high‑efficiency passive ventilation
- Large ventilation cross‑section, effectively discharge workshop waste heat, steam and industrial waste gas
- Integrate ventilation and daylighting, cut energy cost for lighting and mechanical ventilation equipment
- Anti‑corrosion frame material, adapt humid, dusty, coastal industrial environment
- Modular continuous assembly along roof ridge, flexible length according to project ventilation calculation
- Support electric group control, optional fire‑alarm linkage for emergency smoke‑exhaust requirement
| Item | Specification |
|---|---|
| Main Frame Material | Hot‑dip galvanized steel / Aluminum alloy |
| Daylighting Panel | FRP translucent panel / Polycarbonate multi‑wall sheet |
| Installation Position | Roof ridge continuous installation |
| Driving Mode | Electric push‑rod synchronous drive / Manual drive |
| Sealing Component | Aging‑resistant EPDM rubber strip |
| Function | Natural ventilation, daylighting, optional fire smoke‑vent linkage |
| Wind‑load Resistance | Standard 850Pa, reinforced version available |
| Snow‑load Capacity | Standard industrial‑zone grade, customizable for heavy‑snow region |
| Total Length | Custom continuous splicing according to project demand |
1. Raw‑material inspection for steel/aluminum profile, daylighting panel and driving components.
2. CNC cutting, bending and welding for arched shell and base frame.
3. Surface anti‑corrosion treatment: galvanizing or powder coating.
4. Daylighting panel cutting, sealing‑strip pre‑installation.
5. Drive mechanism assembly and pre‑opening‑closing test inside factory.
6. Whole‑unit inspection before packing and shipment.
Frame thickness and welding quality inspection; daylighting panel UV‑resistance test; sealing‑strip aging sampling test; drive component cycle‑life test; whole‑unit rain‑water‑spraying leakage test; multi‑unit synchronous linkage debugging test.
Steel‑structure manufacturing workshops, thermal‑processing plants, textile factories, warehouses, large‑span industrial buildings, ventilation‑renovation projects for existing factories.
Roof ridge purlin shall bear skylight dead‑load and wind‑snow load; reserve sufficient installation space at roof ridge; provide stable power supply for electric driving system; strictly handle waterproof treatment at base‑roof joint position. We provide complete installation technical drawing for construction‑side reference.
Quarterly: Clean sundries in drainage trough to prevent water‑channel blockage.
Half‑yearly: Check sealing strip aging condition, inspect fastener tightness.
Annual: Perform full‑stroke opening‑closing test for driving mechanism; check electric circuit safety; replace aging sealing accessories if necessary.
What is the air exchange capacity of arched side‑open skylight?
Single unit delivers large ventilation cross‑section, suitable for continuous ridge‑mount installation to maximize air exchange volume.
Can arched skylight close completely in heavy rain?
Side‑opening structure with multi‑layer sealing system; it shall keep closed during heavy rainfall to avoid rain splash into building interior.
What frame material options are available?
Hot‑dip galvanized steel or aluminum alloy frame, surface anti‑corrosion coating optional for coastal corrosive environment.
Is it suitable for ridge installation along roof?
Yes, it is specially designed for roof ridge continuous layout, fit most steel‑structure factory ridge openings.
What driving choices for opening‑closing?
Electric push‑rod group drive, manual drive for small‑size projects; synchronous control for multi‑unit linkage.
Can arched skylight work for dust‑producing workshop?
Applicable for dust‑generating plants; regular cleaning of translucent panels and drainage channel is required.
What translucent panel choices?
FRP daylighting panel or polycarbonate multi‑wall sheet, anti‑UV surface coating as standard.
Does arched skylight support fire smoke exhaust function?
Can be configured with fire‑linkage control system to meet smoke‑vent requirement under fire‑protection code.
What snow‑load capacity can it withstand?
Standard snow‑load meets general industrial zone requirement; reinforced frame solution for heavy‑snow area.
Can you provide BIM data or installation drawings?
We supply 2D installation drawings, material list and technical specification for project submission.
Please inform us of your roof ridge length, local wind‑snow load condition, ventilation volume requirement, driving mode and anti‑corrosion demand. We will offer customized technical proposal and competitive quotation for your industrial roof ventilation project.
Technical datasheet and installation drawings can be delivered upon your inquiry.
Contact Our Experts And Get A Free Consultation!
Our mission is to offer "High Quality" & "Good Service" & "Fast Delivery" to help our clients to gain more profits.