Quality Sound Insulated Flexible High Speed Door Pin Type Noise Reduction For Spraying Workshop factory
<
Quality Sound Insulated Flexible High Speed Door Pin Type Noise Reduction For Spraying Workshop factory
Quality Sound Insulated Flexible High Speed Door Pin Type Noise Reduction For Spraying Workshop factory
>

Sound Insulated Flexible High Speed Door Pin Type Noise Reduction For Spraying Workshop

Product Summary

Sound‑Insulated Pin‑Type Flexible Stacking Door | Noise Reduction For Spraying Workshop This sound‑insulated pin‑type flexible stacking door is developed for high‑noise industrial workshops such as sandblasting and large‑scale spraying booth. On the basis of mature pin‑shape overhead stacking ...

Product Custom Attributes

Door Type:
Flexible Stacking
Feature:
Sound Insulated
Application:
Spraying Workshop
Noise Level:
Low Noise
Reduction:
Yes
Highlight:

Sound Insulated Flexible Fast Door

,

Noise Reduction Flexible Stacking Door

,

Flexible High Speed Door for Workshop

Product Description

Sound‑Insulated Pin‑Type Flexible Stacking Door | Noise Reduction For Spraying Workshop

This sound‑insulated pin‑type flexible stacking door is developed for high‑noise industrial workshops such as sandblasting and large‑scale spraying booth. On the basis of mature pin‑shape overhead stacking structure without ground rail, it adopts multi‑layer composite sound‑absorbing insulated curtain. The internal high‑density sound‑absorbing interlayer effectively blocks noise outward transmission, while retaining large‑span opening capacity and strong wind‑resistance. Truss‑beam structure is optimized for thickened composite curtain weight, to ensure stable operation. Complete safety anti‑fall protection system is reserved. It solves the noise‑isolation demand of super‑large openings for noise‑intensive workshops. Support custom‑made noise‑reduction grade, dimension and observation‑window configuration for industrial projects.

Product Overview

Traditional pin‑type flexible stacking door focuses on wind‑resistance and large‑span performance, with ordinary single‑layer fabric without obvious noise‑reduction function. This sound‑insulated version adds composite sound‑absorbing interlayer inside curtain, achieves noise‑isolation effect for sandblasting, spraying and impact‑noise workshops. Still no‑ground‑rail design, convenient for large work‑pieces and equipment to pass in and out. It is a targeted solution for environmental‑protection noise‑control requirements of heavy‑industry workshops.

Structure Design
Sound‑Insulated Composite Curtain & Load‑Bearing Structure

Multi‑layer composite sound‑absorbing insulated curtain, outer layer adopts wear‑resistant waterproof PVC‑polyester fabric, inner equipped with high‑density sound‑absorbing interlayer; optimized‑load pin‑arranged galvanized steel truss wind‑resistant beams; heavy‑load side guide rails; heavy‑duty frequency‑conversion electric hoist lifting system adapting to thick‑curtain weight; wire‑rope lifting mechanism; anti‑fall safety locking device; double‑limit travel control; infrared safety photocell and acousto‑optic alarm; optional sound‑insulated transparent observation window; manual emergency release under power‑off condition.

Core Advantages
  • Multi‑layer composite sound‑absorbing curtain, realize noise‑isolation for high‑noise workshop working condition
  • Retain pin‑shape overhead stacking, no ground‑rail, flat ground for large‑workpiece free passage
  • Truss‑beam structure optimized for thickened composite curtain, guarantee wind‑resistance and running stability
  • Curtain outer‑layer fabric: waterproof, wear‑resistant, anti‑aging, adapt to spraying‑sandblasting workshop environment
  • Complete safety protection: anti‑fall locking, double‑limit, infrared obstacle detection, acousto‑optic warning
  • Support custom noise‑reduction grade, door‑opening dimension and sound‑insulated observation window
Technical Parameters
Item Specification
Product Name Sound‑Insulated Pin‑Type Flexible Stacking Door
Curtain Structure Multi‑Layer Composite Sound‑Absorbing & Sound‑Insulated Curtain
Wind‑Resistant Component Optimized Load‑Bearing Galvanized Steel Truss Beams (Pin‑Type Layout)
Opening Form Over‑Head Pin‑Shape Stacking Folding, No Ground Rail
Running Speed 0.2‑0.5 m/s Adjustable (Heavy‑Duty Frequency‑Conversion Hoist)
Custom Size Project‑Customized According To Workshop Opening
Safety Configuration Anti‑Fall Locking Device, Double‑Limit, Infrared Photocell, Acousto‑Optic Alarm
Observation Window Sound‑Insulated Transparent Window (Optional)
Drive System Heavy‑Duty Frequency‑Conversion Hoist, Manual Emergency Release
Typical Application Sandblasting Workshop, Spraying Booth, High‑Noise Heavy‑Industry Plant
Manufacturing Process

Truss beam cutting‑welding and anti‑rust treatment → composite sound‑insulated curtain hot‑welding compound processing → pin‑type beam‑curtain assembling → heavy‑duty hoist matching and installation → safety anti‑fall device fitting → control cabinet wiring → whole‑door cycle debugging → noise‑insulation performance inspection → export packing.

Quality Control

Composite curtain sound‑insulation performance test; fabric tensile‑strength inspection; truss‑beam welding and load‑bearing verification; whole‑door lifting cycle test; anti‑fall locking simulation test; safety‑device full‑function checking before shipment.

Typical Applications
  • Large sandblasting and shot‑blasting workshop super‑large access doorway
  • Large‑size spraying booth and anti‑corrosion painting workshop
  • Heavy‑impact noise‑intensive manufacturing plant outer gate
  • Semi‑open industrial workshop needing noise‑isolation treatment
  • Environmental‑protection‑oriented heavy‑industry factory large‑span passage
Installation Requirement

Reserve sufficient overhead headroom above doorway; steel‑structure wall shall bear increased total weight brought by sound‑insulated composite curtain; reserve power supply for hoist and control cabinet. We provide complete technical drawings for local installation team to finish on‑site assembly.

Maintenance Suggestion

Prevent sharp objects from scratching curtain surface to avoid damaging internal sound‑absorbing interlayer. Clean curtain surface dust regularly. Check truss‑beam welding point, wire‑rope abrasion and fastening bolts every 6‑12 months. Periodically inspect anti‑fall safety locking device; replace aged curtain and worn accessories timely.

Frequently Asked Questions
What is the core difference of sound‑insulated pin‑type stacking door?
Adopt multi‑layer composite sound‑absorbing and sound‑insulated curtain structure, add high‑density sound‑absorbing interlayer inside curtain, reduce noise outward transmission on the basis of keeping original pin‑type stacking mechanical performance.
How much noise reduction can this door achieve?
According to different composite‑layer configuration, realize different noise‑reduction index; we can match curtain scheme according to customer site noise‑test requirement.
Still no ground‑rail design?
Yes, retain overhead pin‑shape stacking without ground rail, ground keeps flat for large‑equipment entry‑exit in spraying and sandblasting workshop.
Is wind‑resistance performance affected after adding sound‑insulated interlayer?
Truss beam layout and intensity are optimized for thickened composite curtain, guarantee whole‑door wind‑resistant capacity will not decline.
Which workshop scenarios fit this sound‑insulated door?
Mainly for sandblasting workshop, large spraying booth, heavy‑impact noise production workshop, reduce noise pollution spread to outside area.
Can we install observation window on sound‑insulated curtain?
Sound‑insulated transparent observation window is optional, match overall noise‑reduction performance of whole door.
What safety devices are configured?
Wire‑rope breakage anti‑fall locking device, double‑limit control, infrared safety photocell, acousto‑optic alarm, emergency‑stop button.
What drive system is used?
Heavy‑duty frequency‑conversion electric hoist, adapt to increased weight of sound‑insulated composite curtain; keep manual emergency release for power‑off situation.
Can it work under outdoor open‑air environment?
Support outdoor application, composite curtain has waterproof and anti‑aging performance, suitable for semi‑open spraying‑sandblasting workshop.
What maintenance points for sound‑insulated stacking door?
Avoid sharp‑object scratch on curtain surface to prevent damage to internal sound‑absorbing interlayer; inspect truss beam, wire rope and sealing strip every 6‑12 months.
Request Quotation & Technical Drawing

Please provide doorway dimension, site noise‑reduction requirement, installation environment and other special demands. We provide targeted sound‑insulated solution and project quotation.

Contact us for OEM sound‑insulated pin‑type flexible stacking door solutions for your high‑noise workshops.

Contact Our Experts And Get A Free Consultation!

Our mission is to offer "High Quality" & "Good Service" & "Fast Delivery" to help our clients to gain more profits.