Quality Heavy Duty Commercial Steel Fire Rated Door Public Buildings Fire Proof Steel Door factory
<
Quality Heavy Duty Commercial Steel Fire Rated Door Public Buildings Fire Proof Steel Door factory
Quality Heavy Duty Commercial Steel Fire Rated Door Public Buildings Fire Proof Steel Door factory
Quality Heavy Duty Commercial Steel Fire Rated Door Public Buildings Fire Proof Steel Door factory
>

Heavy Duty Commercial Steel Fire Rated Door Public Buildings Fire Proof Steel Door

Product Summary

COMMERCIAL FIRE‑RATED STEEL DOOR Commercial Steel Fire‑Rated Door | Fire Safety Door for Public Buildings High‑performance commercial steel fire‑rated door designed for public building fire compartment and emergency evacuation. Multiple fire‑rating grades, RAL powder coating finish, certified fire ...

Product Custom Attributes

Door Type:
Fire Rated
Material:
Steel
Application:
Commercial Public Building
Fire Rating:
Certified
Feature:
Fire Safety
Highlight:

Commercial Steel Fire Rated Door

,

Public Building Fire Safety Door

,

Heavy Duty Steel Fire Rated Door

Product Description

COMMERCIAL FIRE‑RATED STEEL DOOR

Commercial Steel Fire‑Rated Door | Fire Safety Door for Public Buildings

High‑performance commercial steel fire‑rated door designed for public building fire compartment and emergency evacuation. Multiple fire‑rating grades, RAL powder coating finish, certified fire hardware, optional fire‑proof vision glass. Widely applied for hotel, hospital, office building and shopping mall fire escape passages.

30‑120min Fire Resistance Single & Double Leaf RAL Powder Coating Intumescent Smoke Seal Panic Exit Bar Fire Vision Window

Heavy Duty Commercial Steel Fire Rated Door Public Buildings Fire Proof Steel Door

Main Product Variants

Single‑Leaf Commercial Fire Door

Standard single‑leaf for normal pedestrian escape routes.

  • Standard dimension 900/1000*2100mm
  • In‑swing / out‑swing direction optional
  • Stairwell, office corridor, utility room
  • RAL custom color powder coating

Double‑Leaf Commercial Fire Door

Double‑leaf for high‑flow public evacuation opening.

  • Symmetric or asymmetric leaf design
  • For hospital lobby, mall exit, large corridor
  • Complete panic bar hardware set
  • Custom width for public building code

Fire Door With Observation Vision Panel

Certified fire‑resistant glass for visual observation.

  • Compliant fire‑rated glass panel
  • Limited glass area follow fire safety standard
  • Hospital ward, lab, control room corridor
  • Maintain full fire‑stop performance

Fire‑Rated Service Room Door

Compact fire door for electrical & mechanical equipment room.

  • Small‑size compact fire‑rated assembly
  • For basement, pump room, transformer room
  • Simple robust structure, low maintenance
  • Full fire‑rating certification

Technical Specification

Parameter 30min Commercial Fire Door 60‑90min Commercial Fire Door 120min Heavy‑Duty Commercial Fire Door
Door Leaf Material Galvanized steel shell, mineral wool filling Thickened galvanized steel, high‑density mineral wool Heavy‑gauge galvanized steel, enhanced fire‑resistant core
Leaf Thickness 45‑50mm 50‑55mm 60‑65mm
Surface Treatment RAL powder coating RAL powder coating RAL powder coating
Sealing Perimeter intumescent fire‑smoke seal Full‑perimeter intumescent seal Dual‑layer intumescent sealing strip
Core Hardware Fire hinges, door closer, fire lock Certified fire hinges, closer, optional panic bar Heavy‑duty fire hardware, panic exit push‑bar
Typical Site Office, general utility room Hotel, hospital, shopping mall corridor High‑rise building critical fire compartment

Heavy Duty Commercial Steel Fire Rated Door Public Buildings Fire Proof Steel Door

Core Components & Features

Commercial steel fire‑rated door adopts galvanized steel bending‑welded structure, filled with fire‑resistant mineral wool. Intumescent sealing strip will expand under high temperature to block flame and smoke spreading. All hardware must be fire‑safety certified to satisfy public building fire‑code requirements.

  • Intumescent Fire‑Smoke Seal: High‑temperature expansion seals gaps between leaf and frame, prevents smoke leakage.
  • Certified Fire Hinges: High‑temperature resistant, quantity matched to door leaf weight to avoid fire‑time deformation.
  • Adjustable Fire‑Rated Door Closer: Ensures reliable automatic self‑closing for fire compartment isolation.
  • Panic Exit Push‑Bar: Quick inward push opening for mass crowd emergency evacuation.
  • RAL Custom Powder Coating: Rich color options to match interior decoration style of commercial buildings.

Manufacturing & Installation Guidance

Production Process

  • Confirm fire rating, dimension, swing direction, vision window and RAL color
  • Laser cutting, bending and welding for door leaf & frame
  • Fill fire‑resistant mineral wool core, fit intumescent seal strip
  • Powder coating surface finish, assemble certified fire hardware
  • Gap inspection & closing performance test before shipment

On‑Site Installation Points

  • Fix door frame firmly to concrete wall, guarantee verticality Control uniform gap between leaf and frame for sealing performance Install full set certified fire hardware strictly per specification Debug door‑closer closing speed and latch function Deliver complete certification documents for building acceptance

Application Scenarios

Commercial Public Buildings

  • Hotel guest floor stairwell & corridor
  • Hospital ward, treatment area fire partition
  • Shopping mall emergency escape exit
  • Office building stairwell and equipment room

Building Compliance Requirement

  • Fire compartment separation for high‑rise building
  • Basement fire escape passage
  • Mechanical & electrical equipment room fire isolation
  • Public evacuation route safety barrier

Routine Maintenance Checklist

  • Check door‑closer to ensure fire door can self‑close and latch completely.
  • Inspect intumescent seal strip for damage or missing parts, replace when broken.
  • Tighten hinge bolts to prevent door leaf sagging and abnormal gap.
  • Forbid fixing fire door in permanent open position against fire safety code.
  • Test panic push‑bar function regularly for emergency evacuation readiness.

Heavy Duty Commercial Steel Fire Rated Door Public Buildings Fire Proof Steel Door

FAQ

1. Where to use commercial steel fire‑rated door?

Mainly for stairwells, escape routes, corridors, equipment rooms in hotels, hospitals, offices and shopping malls.

2. What standard sizes are available?

Standard 900*2100,1000*2100,1200*2100mm; custom dimensions also supported.

3. Can I choose different surface paint colors?

Yes, powder‑coating RAL color system for matching interior decoration requirement.

4. What hardware comes as standard?

Fire hinges, door closer, fire lock; panic push‑bar for emergency exit outward opening.

5. What documents for building inspection?

Fire test certificate, test report, installation manual, CAD drawings for tender submission.

Contact Our Experts And Get A Free Consultation!

Our mission is to offer "High Quality" & "Good Service" & "Fast Delivery" to help our clients to gain more profits.